SITE-001 · Hospital
STATE: NORMAL_GRID
LIVE STREAM
AGE: 0.2s
DSP: 2.81 ms
System Healthy Automatic Connected 0 active alarms
Synced 14:28

Energy Summary พลังงานสะสมและมูลค่าประมาณการ

DAILY ENERGY
112.00 kWh
Revenue ฿392.00
↗ 4.7% ↗ 5.1%
MONTHLY ENERGY
3,409.28 kWh
Revenue ฿11,932.48
↗ 8.2% ↗ 9.3%
TOTAL ENERGY
17,384.10 kWh
Revenue ฿60,844.35
↗ 12.4% ↗ 11.8%
CARBON CREDIT
8.69 tCO₂e
Est. Value ฿869.20
↗ 10.5% ↗ 6.8%

Live Power กำลังไฟและสถานะปัจจุบัน

GRID IMPORT
IMPORTING
23.8 kW
IMPORT
Today 91.8 kWh
Total Load 218.0 kWh
EXPORT
Today 0.0 kWh
Solar Produced 112.0 kWh
BATTERY
SOC 85%
0.0 kW
CHARGE
from Grid 5.9 kWh
from PV 17.8 kWh
DISCHARGE
to Normal Load 10.8 kWh
to Critical Load 2.7 kWh
SOLAR
GENERATING
18.5 kW
Current Generation
DAILY PRODUCTION
112.0 kWh
Total (Today) 112.0 kWh
Export 0.0 kWh
LOAD
NORMAL
42.3 kW
CRITICAL LOAD
Active Power 24.4 kW
57%
NORMAL LOAD
Active Power 17.9 kW
43%
Single-Line Power Flow Topology (SLD) · Site-001 Hospital Microgrid
PEA Grid Solar PV / DVR PCS Hospital Loads
24.0 kW 18.0 kW 6.0 kW 6.0 kW 18.5 kW 24.5 kW PEA GRID (JANITZA) 24.0 kW PF 0.980 · THD 1.4% DVR-PLUS 30kVA 0.0 kW STS Closed · <2.8ms Sag CRITICAL LOAD 24.5 kW Fl.1 ICU/OR · PM2230 NORMAL LOAD 18.0 kW Fl.4 Wards · PM2230 BESS EBC 768V 85.0% 768.2 V · 0.0 A · 29.5°C SOLAR PV (HUAWEI) 18.5 kW SUN2000-30KTL · 164.5 kWh
Phase Electrical Parameters TRUE RMS
Phase Voltage (V) Current (A) THD-V (%) Status
Phase A 381.2 36.5 1.82 Normal
Phase B 380.5 35.8 1.79 Normal
Phase C 381.8 36.9 1.85 Normal
Annunciator Alarms
Time Severity Event State
12:40:12 INFO BMS Modbus RTU ID:1 heartbeat valid (COM1 9600 bps) HEALTHY
12:15:30 INFO DVR-PLUS 30 kVA PCS fast-wake armed (<2.8 ms) HOT READY
11:58:02 INFO PEA Incomer Janitza sync confirmed (380V / 50.02 Hz) NOMINAL
GRID FREQUENCY
SYNC LOCKED
50.02 Hz
STABILITY
Sync Window±0.02 Hz
Nominal50.00 Hz
PHASE LOCK
PLL Lock99.99 %
Phase Angle0.0° Ph-A
REACTIVE POWER
DSP ACTIVE
15.2 kVAr
COMPENSATION
ModeInductive Act.
Power Factor0.992 Ind
OPTIMIZATION
Target PF1.000
THD-Q0.8 %
APPARENT LOAD
85.3% LOAD
256.1 kVA
CAPACITY
Factor85.3 %
Active Power252.0 kW
HEADROOM
Rating300.0 kVA
Spare43.9 kVA
NEUTRAL CURRENT
BALANCED
1.2 A
BALANCE
Phase Unbal0.78 %
Return StatusSafe Return
SAFETY
Neutral-Gnd0.4 V
Trip Limit< 20.0 A

Energy Flow

24-hour overview · stacked power contributions
Solar
Battery
Grid
Total Load
Battery SOC
Digital Storage Oscilloscope: 3-Phase Bus Waveforms
RUNNING
Timebase:
Volt Scale:
Channels:
Trigger: LINE LOCK · 50.00 Hz
RMS: 402.5 V
V_PP: 569.2 V
SAMPLE RATE: 40 kSPS
COUPLING: AC/DC DIRECT
Voltage THD (Total)
1.8 %
Limit: < 3.0 % (IEEE 519)
Current THD (Total)
3.2 %
Limit: < 5.0 %
Voltage Unbalance
0.78 %
IEC 61000 Limit: < 2.0 %
Harmonic Filter
ACTIVE
DSP Real-time Cancellation
Harmonic Order Spectrum Analysis (Fundamental 50 Hz to 25th Harmonic) FFT WINDOW: 10 CYCLES

LiFePO4 High-Voltage Battery Bank (EBC 768V)

Site-001 · Modbus RTU Slave ID 1 · 20 Series Modules (20S1P) · 61.44 kWh
BMS ONLINE COM1 · 9600-8N1
STATE OF CHARGE
OPTIMAL
85.0 %
ENERGY
Stored52.2 kWh
Capacity61.44 kWh
HEALTH
SOH99.5 %
Cycles142 Cyc
PACK DC BUS
CONNECTED
768.2 V
CURRENT
Flow0.0 A
ModeFloat Standby
RATINGS
Nominal V768.0 V
Max Limit876.0 V
CELL IMBALANCE
BALANCED
12 mV
EXTREMES
Max Cell3.205 V (M14)
Min Cell3.193 V (M08)
LIMITS
Warn Limit< 150 mV
Trip Cutoff300 mV
THERMAL & SAFETY
NORMAL
29.5 °C
SENSORS
Pack Avg28.8 °C
Ambient24.2 °C
PROTECTION
Max Limit< 55.0 °C
Alarms0 Active
Battery Rack Architecture · 20 Series Modules (20S1P)
PWR RUN COM ALM
HV CONTROL BOX & PDU BMS Master Unit · Main DC(+) DC(-) Contactors Closed · Fast Fuse 160A
CONTACTOR CLOSED ISO > 50 MΩ
MOD 0138.41V
3.201 V/cell
29.4 °CBal: OK
MOD 0238.39V
3.199 V/cell
29.2 °CBal: OK
MOD 0338.42V
3.202 V/cell
29.5 °CBal: OK
MOD 0438.38V
3.198 V/cell
29.1 °CBal: OK
MOD 0538.40V
3.200 V/cell
29.3 °CBal: OK
MOD 0638.41V
3.201 V/cell
29.4 °CBal: OK
MOD 0738.36V
3.197 V/cell
29.0 °CBal: OK
MOD 08MIN 3.193V
3.193 V/cell
28.9 °C-7 mV ΔV
MOD 0938.42V
3.202 V/cell
29.6 °CBal: OK
MOD 1038.40V
3.200 V/cell
29.3 °CBal: OK
MOD 1138.39V
3.199 V/cell
29.2 °CBal: OK
MOD 1238.44V
3.203 V/cell
29.7 °CBal: OK
MOD 1338.41V
3.201 V/cell
29.4 °CBal: OK
MOD 14MAX 3.205V
3.205 V/cell
29.8 °C+5 mV ΔV
MOD 1538.40V
3.200 V/cell
29.3 °CBal: OK
MOD 1638.38V
3.198 V/cell
29.1 °CBal: OK
MOD 1738.42V
3.202 V/cell
29.5 °CBal: OK
MOD 1838.39V
3.199 V/cell
29.3 °CBal: OK
MOD 1938.41V
3.201 V/cell
29.4 °CBal: OK
MOD 2038.40V
3.200 V/cell
29.2 °CBal: OK
Cell Voltage Dispersion (20S Modules) TOLERANCE ±15mV (PASS)
3.220V 3.200V 3.180V M01: 3.201V M01 M02: 3.199V M02 M03: 3.202V M03 M04: 3.198V M04 M05: 3.200V M05 M06: 3.201V M06 M07: 3.197V M07 M08: 3.193V (MIN) M08 M09: 3.202V M09 M10: 3.200V M10 M11: 3.199V M11 M12: 3.203V M12 M13: 3.201V M13 M14: 3.205V (MAX) M14 M15: 3.200V M15 M16: 3.198V M16 M17: 3.202V M17 M18: 3.199V M18 M19: 3.201V M19 M20: 3.200V M20
Min Cell 3.193 V (M08)
Mean Cell 3.200 V
Max Cell 3.205 V (M14)
Delta (ΔV) 12 mV (Pass)
BESS EBC Modbus RTU Sequential Registers SLAVE ID 1
Address Parameter Description Raw Telemetry Diagnostic
Reg 38 Pack Terminal Voltage (0.1V) 768.2 V Normal Range
Reg 39 Pack Battery Current (0.1A) 0.0 A Float Standby
Reg 40 State of Charge - SOC (0.1%) 85.0 % Optimal
Reg 41 State of Health - SOH (0.1%) 99.5 % Healthy
Reg 35 Maximum Cell Voltage 3.205 V Balanced
Reg 36 Minimum Cell Voltage 3.193 V Balanced
Reg 37 Maximum Cell Temperature 29.5 °C Cooling OK
Reg 132-139 Protection Alarm Bitfields 0x0000 Zero Alarms
ANSI / IEEE C37 Hardware Protection Matrix COORDINATED SETPOINTS
ANSI Code Protection Function Trip Setpoint Response Delay Arm Status
59 Overvoltage Protection 110.0 % (440 V) < 10 ms Armed
27 Undervoltage Protection 85.0 % (340 V) < 10 ms Armed
50/51 Instantaneous Overcurrent 120.0 % (360 A) < 1 ms Armed
81O/U Under / Over Frequency 47.5 - 52.5 Hz < 100 ms Armed
49 Thermal Overload Inverter Sink > 85.0 °C < 500 ms Armed
COM1: BESS EBC 768V BMS
POLLING OK
9600 bps 8N1 · Slave ID: 1 · /dev/ttyUSB0
COM2: DVR-PLUS PCS 30kVA
POLLING OK
19200 bps 8N1 · Slave ID: 2 · /dev/ttyUSB1
COM3: PM2230 Fl.4 (Normal)
POLLING OK
9600 bps 8N1 · Slave ID: 6 · /dev/ttyUSB2
COM4: PM2230 Fl.1 (ICU/OR)
POLLING OK
19200 bps 8E1 · Slave ID: 8 · /dev/ttyUSB3
Modbus TCP: SmartLogger2000
CONNECTED
192.168.6.200:502 · Huawei PV / Janitza / Weather
Edge Gateway: Seeed J4012
HEALTHY
Jetson Orin Nano 8GB · Python 3.14 · 6-Cores
PCS MODE:STANDBY
DC BUS:750.2 Vdc
ACTIVE POWER:0.0 kW
DC CURRENT:0.0 A
BESS SOC:85.0 %
IGBT TEMP:42.4 °C
PWM GATES:READY (FAST-WAKE)
PCS Operational Mode & Setpoints (Bi-Directional Converter) DVR-PLUS RMS 30 kVA (COM2 ID: 2)
Select active operational profile for the Bi-Directional Power Conversion System (PCS). All setpoint modifications write directly to DSP control registers with ISA-101 dual-stage verification.
STANDBY
HOT READY
DC Link pre-charged at 768 Vdc (LiFePO4 EBC 20S rack). PWM gate pulses inhibited to eliminate switching losses. Sub-cycle fast-wake auto-ignition (<2.8 ms) upon grid sag event.
CHARGE
AC → DC
Rectifier operation: draws regulated power from AC bus / PV to charge LiFePO4 battery pack with programmable power, current limits, and zero-export buffer protection.
DISCHARGE
DC → AC
Inverter operation: injects power into facility bus for load peak-shaving (>45 kW), series sag boost assistance (<2.8 ms), or scheduled dispatch with deep-discharge protection.
Standby Operational Parameters & Fast-Wake Readiness
Precharge Contactor State
CLOSED / 768V BUS ENERGIZED
Idle Standby Inverter Loss
0.14 kW (Control & Auxiliary)
Battery Charge Parameters (AC → DC Rectifier Mode)
Battery Discharge Parameters (DC → AC Inverter Mode)
PEA Incomer & Microgrid Dispatch Limits JANITZA UMG 96RM
Site-001 Microgrid Dispatch Logic EMS MASTER ACTIVE
• P_grid = P_load (PM2230 Fl1+Fl4) - P_solar (Huawei) - P_pcs
• If P_grid > 45.0 kW: State → PEAK_SHAVING (Discharge 15 kW)
• If P_grid < 3.0 kW: State → ZERO_EXPORT (Charge 10 kW / Derate)
• Sub-cycle sag detection <2.8 ms triggers series boost
High-Precision Sequence of Events (SOE Audit Log) RESOLUTION: 1.0 ms
Timestamp (UTC) Tag ID Event Category Before After Operator / Source
2026-09-15 05:14:22.180 SETPOINT_VREF Config Modification 398 V 400 V Station Admin
2026-09-15 03:42:01.050 RELAY_TRIP_CLR Fault Clearance SAG_ALERT NORMAL DSP Autoreclose
2026-09-15 00:00:00.000 BESS_DAILY_DIAG Diagnostics FLOAT FLOAT BMS Routine
Subsystem Asset Maintenance Ledger
Subsystem Asset Last Inspection Next Scheduled Overhaul Interval Health Index Condition
LiFePO4 EBC 768V Battery Rack (20S) 2026-07-15 2026-10-15 90 Days SOH 99.5% Normal
DVR-PLUS 30 kVA PCS Forced Air Cooling 2026-08-01 2026-11-01 90 Days Airflow Nominal Normal
reComputer J4012 Edge Gateway & Python EMS 2026-08-10 2026-11-10 90 Days Temp 38.2°C Normal
Janitza UMG 96RM & STS Transfer Switch 2026-05-20 2027-05-20 365 Days Calibrated Normal